Vue de la page 26
Register
Number
XVG/eXVG Parameters
Name
Write
Access
Description Type
3073 IDM_ADCB3GAINOFF RO
Analog input w/Auto ADC gain/off applied, cnts 0-
4095
U16
3074 IDM_ADCB4GAINOFF RO
Analog input w/Auto ADC gain/off applied, cnts 0-
4095
U16
3075 IDM_ADCB5GAINOFF RO
Analog input w/Auto ADC gain/off applied, cnts 0-
4095
U16
3076 IDM_ADCB6GAINOFF RO
Analog input w/Auto ADC gain/off applied, cnts 0-
4095
U16
3077 IDM_ADCB7GAINOFF RO
Analog input w/Auto ADC gain/off applied, cnts 0-
4095
U16
3078 IDM_ADCB5A RO Muxed analog input for ADCAI3, counts 0-4095 U16
3079 IDM_ADCB5B RO Muxed analog input for ADCAI4, counts 0-4095 U16
3080 IDM_ADCB5C RO Muxed analog input for ADCAI5, counts 0-4095 U16
3081 IDM_ADCCALLOW RO ADC A 0.22V ref calibration counts 0 – 4095 U16
3082 IDM_ADCCALHI RO ADC B 2.5V Ref Calibration counts 0 – 4095 U16
3083 IDM_SOLDUTY RO
Solenoid duty cycle, # of times on/1000 updates, for
debug
U16
3084 IDM_LOOPCNT RO Main task loop cycles per 125ms, for debug U16
3085 IDM_BUFINDEX1 W0
Advanced diagnostics histogram bucket index and
ADC channel index
U16
3086 IDM_BUFINDEX2 W0 ADC buffer index U16
3087 IDM_ADCBUFVAL RO
ADC input buffer array value, for test.
ADCBUFVAL[BUFINDEX1][BUFINDEX2]
U16
3088 IDM_DEMANDSTATUS RO
Demand before position interpolation, value range:
683 to 3413
U16
3089 IDM_AOUT0PWMCTS RO Analog output 0 PWM value: 0 to 4095 U16
3090 IDM_AOUT1PWMCTS RO Analog output 1 PWM value: 0 to 4095 U16
3091 IDM_AOUT2PWMCTS RO Analog output 2 PWM value: 0 to 4095 U16
3092 IDM_FADCCALHI RO Fault Log, ADCCALHI at time of fault U16
3093 IDM_FADCCALLOW RO Fault Log, ADCCALLOW at time of fault U16
3094 IDM_TESTCTRL W0
Use to trigger EEPROM tasks (sets bits in
ETFLAGS). Fully functional using PECC protocol.
Using Modbus, only fault read task allowed. See
ETFLAGS for bits.
U16
3095 IDM_ETFLAGS RO
Test parameter for viewing scheduled EEPROM
tasks: b0=fault save, b1=fault reset, b2=fault read,
b3=AdvDiag save, b4=EEPROM reset (use w/b3)
U16
3096 IDM_FLTBUF RO
Buffer number of next fault record to be saved: 0 to 16
(16 = buffer 0)
U16
3097 IDM_CLSEC RO Lost communication seconds counter U16
3098 IDM_LVDTCOUNT RO ADC count from LVDT U16