Number
XVG/eXVG Parameters
Name
Write
Access
Description Type
3014 IDM_ADCINPRES RO Input Pressure counts, range 0-4095 U16
3015 IDM_ADCAI0 RO Analog Input 0 (demand), range 0-3413 U16
3016 IDM_ADCOUTPRES RO Output Pressure counts, range 0-4095 U16
3017 IDM_ADCAI1 RO Analog Input 1 counts, range 0 – 4095 U16
3018 IDM_ADCDELTAPRES RO Not used U16
3019 IDM_ADCAI2 RO Analog Input 2 counts, range 0 – 4095 U16
3020 IDM_ADCGASTEMP RO Gas Temperature counts U16
3021 IDM_ADCAI3 RO Analog Input 3 counts, range 0 – 4095 U16
3022 IDM_ADCSOLTEMP RO Solenoid temp counts, not used U16
3023 IDM_ADCAI4 RO Analog Input 4 counts, range 0 – 4095 U16
3024 IDM_ADCMOTORCUR RO Motor Current counts, range 0 - 4095 U16
3025 IDM_ADCAI5 RO Analog Input 5 counts, range 0 – 4095 U16
3026 IDM_FFAULTFLGS RO Fault Report Variable, not used U16
3027 IDM_FVERSION RO Fault Report Variable, not used U16
3028 IDM_FRUNTMMINS RO Fault Log, Run Time Minutes of fault log U16
3029 IDM_FRUNTMSECS RO Fault Log, Run Time Seconds of fault log U16
3030 IDM_SETUPERROR RO Setup Validation Error Code, 0 = No Errors U16
3031 IDM_TESTFLAGS W3 Test Flags (SW debug use only) U16
3032 IDM_FMODE RO Fault Report Variable, not used U16
3033 IDM_CALFLAGS W1
Calibration Flags:
Bit0=Set Valve in Calibration State.
The following bits active only in cal state:
Bit1=Enable Feedback Override,
Bit2=Set Solenoid Duty Cycle Out to 50%
Bit3=Read ADC A raw cal voltage into
IDM_ADCACALADC
Bit4=Read ADC B raw cal voltage into
IDM_ADCBCALADC
Bit5=Write parameters to EEPROM Bit6=Reset
IDM_TOTALHRS to 0 if parameter IDM_DATE =
666
U16
3034 IDM_CALAOUT0 W3 Analog Output 0 DAC Value, counts 0-4095 U16
3035 IDM_ADCBCALADC RO ADC B 2.5V Ref Calibration counts 0-4095 U16
3036 IDM_AOUT1 W3 Analog Output 1 DAC Value, counts 0-4095 U16
3037 IDM_AOUT2 W3 Analog Output 2 DAC Value, counts 0-4095 U16
3038 IDM_FIRMWAREVER RO Firmware Version U16
3039 IDM_AOUT0 RO AO0 DAC Value, counts 0-4095 U16
3040 IDM_DIN0 RO
DI0 Value: (reserved for external Run/Stop)
Bit0-Bit3=DI0-DI3 – only used if valve enters
CAL_STATE
U16
3041 IDM_DOUT0 W3
Digital Output 0 Value: (reserved for Fault Output)
Bit0-Bit5=O0-O3, 485TXENA, 485TXENB – only
valid if valve enters CAL_STATE, otherwise for SW
test
U16
25