Hamilton-sundstrand-company Fuel Metering Valves XVG Manuel d'utilisateur Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Corresponding Demand Type
Pre-
Cal
Default
5670 5671 IDM_POSTBL35 W2 Counts: 2218.6250, 13.0mA Demand U32 567968
5672 5673 IDM_POSTBL36 W2 Counts: 2389.2500, 14.0mA Demand U32 611648
5674 5675 IDM_POSTBL37 W2 Counts: 2559.8750, 15.0mA Demand U32 655328
5676 5677 IDM_POSTBL38 W2 Counts: 2730.5000, 16.0mA Demand U32 699008
5678 5679 IDM_POSTBL39 W2 Counts: 2901.1250, 17.0mA Demand U32 742688
5680 5681 IDM_POSTBL40 W2 Counts: 3071.7500, 18.0mA Demand U32 786368
5682 5683 IDM_POSTBL41 W2 Counts: 3242.3750, 19.0mA Demand U32 830048
5684 5685 IDM_POSTBL42 W2 Counts: 3413.0000, 20.0mA Demand U32 873728
Table 17: Position Interpolation Table Parameters
9.1.3 Stroke Position Parameters
For XVG/eXVG low measurement and flow control accuracy improvement, the CdA
values are calculated based not only stroke position (using stroke- CdA interpolation
table) but also on pressure ratio condition.
The following Stroke Position Table lists default values of fifteen stroke positions that
will be used in CdA values calculation. Table values are (stroke value*2
24
).
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Corresponding Stroke Type
Default
Value
5900 5901 IDM_STROKETBL0 W4 0.005 U32 83886
5902 5903 IDM_STROKETBL1 W4 0.01 U32 167772
5904 5905 IDM_STROKETBL2 W4 0.015 U32 251658
5906 5907 IDM_STROKETBL3 W4 0.03 U32 503316
5908 5909 IDM_STROKETBL4 W4 0.045 U32 754975
5910 5911 IDM_STROKETBL5 W4 0.0625 U32 1048576
5912 5913 IDM_STROKETBL6 W4 0.078125 U32 1310720
5914 5915 IDM_STROKETBL7 W4 0.09 U32 2097152
5916 5917 IDM_STROKETBL8 W4 0.1 U32 2621440
5918 5919 IDM_STROKETBL9 W4 0.125 U32 2936013
5920 5921 IDM_STROKETBL10 W4 0.15625 U32 3355443
5922 5923 IDM_STROKETBL11 W4 0.175 U32 3774874
5924 5925 IDM_STROKETBL12 W4 0.2 U32 4194304
5926 5927 IDM_STROKETBL13 W4 0.225 U32 4194472
5928 5929 IDM_STROKETBL14 W4 0.25 U32 4194640
Table 18: Stroke Position Table Parameters
9.1.4 Pressure Ratio Parameters
These pressure ratio values are used in calculation of CdA values based on stroke and
pressure ratio conditions. Table values are (pressure ratio value*2
24
).