Hamilton-sundstrand-company Fuel Metering Valves XVG Manuel d'utilisateur Page 15

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 36
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 14
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Description Type
Default
Value
5508 5509 IDM_SETUPCHECK W4 Setup parameter checksum U32 12345
5510 5511 IDM_SHUTDNFLTS W4
Faults to Shutdown on, same as
IDM_FAULTFLAGS
U32
0
5512 5513 IDM_FAULTOUTCFGL W4
Fault output configuration bit-field, to
configure which fault codes will show on
digital output channel 0. Same bits as
IDM_FAULTFLAGSL
U32
0
5514 5515 IDM_TAT W4
Thermal age threshold for Electronics Age
Warning fault, units of seconds. Fault
disabled if = 0. Range: 0 to 4 billion
U32
0
5516 5517 IDM_TITHRESH W4
Total inches traveled warning fault threshold,
units of inches. Fault disabled if = 0.
Range: 0 to 4 billion
U32
0
7500 7501 IDM_LVDTGAIN W4 LVDT Gain: range 0.1 – 3.0 Float 1
7502 7503 IDM_LVDTOFFSET W4 LVDT Offset: range -200 – 200 Float 0
7504 7505 IDM_ADCAGAIN W4 ADC A Gain: range 0.1 – 3.0, obsolete Float 1
7506 7507 IDM_ADCAOFFSET W4 ADC A Offset: range -200 – 200, obsolete Float 0
7508 7509 IDM_OUTPUTGAIN W4 4-20mA Feedback Gain, Obsolete Float 1
7510 7511 IDM_ADCBGAIN W4 ADC B Gain: range 0.1 – 3.0, obsolete Float 1
7512 7513 IDM_ADCBOFFSET W4 ADC B Offset: range -200 – 200, obsolete Float 0
7514 7515 IDM_DMD420GAIN W4 4-20mA Demand Input Gain: (Obsolete) Float 1.016
7516 7517 IDM_DMD420OFF W4 4-20mA Demand Input Offset: (Obsolete) Float 0
7518 7519 IDM_CONSTR W0
R Gas Constant: must be non-zero, default is
Air
Float
53.34
7520 7521 IDM_CONSTK W0
K Gas Constant: must be non-zero, default is
Air
Float
1.4
7522 7523 IDM_CONSTGC W2
Gc Gas Constant: must be non-zero, default
is Air
Float
32.2
7524 7525 IDM_CONSTZ W2
Z Gas Constant: must be non-zero, default is
Air
Float
1
7526 7527 IDM_FLOWOFFSET W4 Measured Flow Offset: range -1400 to 1400 Float 0
7528 7529 IDM_SUPPRESOFF W4 Supply Pressure Offset: (obsolete) Float 0
7530 7531 IDM_TEMPOFF W4
Gas Temp Sensor Offset: range -39.2 to 39.2
Deg F
Float
0
7532 7533 IDM_SONSUBHYS W4
Subsonic/Subsonic Hysteresis.
Range -0.1 – 0.1
Float
0.03
7534 7535 IDM_DELTAPRESOFF W4 Not used Float 0
7536 7537 IDM_FLOWRANGE W2
Flow Measurement and Control Max Limit:
range 1.0 – 20000.0 PPH
Float
1600
7538 7539 IDM_MAXSTROKE W2 Maximum Stroke: range 0.005 – 0.275 in Float 0.25
7540 7541 IDM_MAXVELOCITY W4 Maximum Velocity: range 0.0 – 0.01 Float
0.0006
25
7542 7543 IDM_KP W4
Position Control Proportional Constant: must
be non-zero
Float
0.038
7574 7545 IDM_KI W4
Position Control Integral Constant: range 0.0
to 0.0156
Float
0.001
7576 7547 IDM_INPRESGAIN W4 Input Pressure Sensor Gain: range 1 – 2 Float 1
15
Vue de la page 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 35 36