Number
XVG/eXVG Parameters
Name
Write
Access
Description Type
5056 5057 IDM_OPS RO
Histogram array parameter for OutletPressure,
seconds
U32
5058 5059 IDM_FS RO
Histogram array parameter for flow measurement,
seconds
U32
5060 5061 IDM_MCS RO Histogram array parameter for MotorCurrent, seconds U32
5062 5063 IDM_DJS RO
Histogram array parameter for demand jitter, seconds
(command change accumulation/sec)
U32
7000 7001 IDM_POSININCHES RO Valve Position in inches Float
7002 7003 IDM_INPUTPRES W3 Input Pressure, PSIA Float
7004 7005 IDM_OUTPUTPRES W3 Output Pressure, PSIA Float
7006 7007 IDM_OUTPCORRECT RO Output Pressure Corrected, PSIA Float
7008 7009 IDM_MEASFLOW RO Measured Flow, PPH Float
7010 7011 IDM_CDAOUT RO CdA specified by demand Float
7012 7013 IDM_MEASUREDCDA RO Measured CdA, calculated from measured position Float
7014 7015 IDM_GASTEMP W3 Gas Temperature, degrees F (includes TEMPOFF) Float
7016 7017 IDM_VOLTS3PT3 RO 3.3V supply voltage, Volts Float
7018 7019 IDM_PRESSRATIO RO Pressure Ratio Float
7020 7021 IDM_DMDININCHES RO Position Demand in inches Float
7022 7023 IDM_FLOWLIMDMD RO Flow Limiting Demand Output Float
7024 7025 IDM_MINFLOWLIM RO Calculated Min Flow Limit Float
7026 7027 IDM_MAXFLOWLIM RO Calculated Max Flow Limit Float
7028 7029 IDM_FLOWLIMRNG RO Calculated Flow Limiting Range Float
7030 7031 IDM_FLOWRNGSCALR RO Flow Range Scaler, Max Flow / Max Counts Float
7032 7033 IDM_SOLTEMP RO Solenoid Temperature, not used Float
7034 7035 IDM_EQCONSTA RO Flow equation constant A Float
7036 7037 IDM_EQCONSTB RO Flow equation constant B Float
7038 7039 IDM_EQCONSTC RO Flow equation constant C Float
7040 7041 IDM_EQCONSTD RO Flow equation constant D Float
7042 7043 IDM_EQCONSTE RO Flow equation constant E Float
7044 7045 IDM_EQCONSTF RO Flow equation constant F Float
7046 7047 IDM_LVDTAPLUSB RO LVDT A+B signal Float
7048 7049 IDM_LVDTAMINUSB RO LVDT A-B signal Float
7050 7051 IDM_FVOLTS3PT3 RO Fault Log, Volts3pt3 at time of fault Float
7052 7053 IDM_FSOLTEMP RO Fault report variable, not used Float
7054 7055 IDM_FINPUTPRES RO Fault Log, InputPres at time of fault Float
7056 7057 IDM_FOUTPUTPRES RO Fault Log, OutputPres at time of fault Float
7058 7059 IDM_FGASTEMP RO Fault Log, GasTemp at time of fault Float
7060 7061 IDM_FFLOWRANGE RO Fault report variable, not used Float
7062 7063 IDM_FMEASFLOW RO Fault Log, MeasFlow at time of fault Float
7064 7065 IDM_FFAULTDATA RO Fault Log, Fault Data at time of fault Float
7066 7067 IDM_FPOSININCHES RO Fault Log, PosInInches at time of fault Float
7068 7069 IDM_FTEMPAMB RO Fault Log, TempAmb at time of fault Float
7070 7071 IDM_FVOLTSPOS15 RO Fault Log, VoltsPos15 at time of fault Float
30
Vue de la page 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 36

Commentaires sur ces manuels

Pas de commentaire