Register
Number
XVG/eXVG Parameter
Name
Write
Access
Description Type
Default
Value
7650 7651 IDM_AO0CUROFF W4 AO0 Current Offset: range -4 to 4 counts Float 0
7652 7653 IDM_AO0VOLTGAIN W4 AO0 Voltage Gain: range 0.72 – 0.80 Float 1
7654 7655 IDM_AO0VOLTOFF W4 AO0 Voltage Offset: range -4 to 4 counts Float 0
7656 7657 IDM_AO1CURGAIN W4 AO1 Current Gain: range 0.72 – 0.80 Float 1
7658 7659 IDM_AO1CUROFF W4 AO1 Current Offset: range -4 to 4 counts Float 0
7660 7661 IDM_AO1VOLTGAIN W4 AO1 Voltage Gain: range 0.72 – 0.80 Float 1
7662 7663 IDM_AO1VOLTOFF W4 AO1 Voltage Offset: range -4 to 4 counts Float 0
7664 7665 IDM_AO2CURGAIN W4 AO2 Current Gain: range 0.72 – 0.80 Float 1
7666 7667 IDM_AO2CUROFF W4 AO2 Current Offset: range -4 to 4 counts Float 0
7668 7669 IDM_AO2VOLTGAIN W4 AO2 Voltage Gain: range 0.72 – 0.80 Float 1
7670 7671 IDM_AO2VOLTOFF W4 AO2 Voltage Offset: range -4 to 4 counts Float 0
7672 7673 IDM_AI0VOLTGAIN W4 AI0 Voltage Gain: range 1.03 – 1.05 Float 1
7674 7675 IDM_AI0VOLTOFF W4 AI0 Voltage Offset: range -(122.6 to 146.6) Float 0
7676 7677 IDM_AI1VOLTGAIN W4 AI1 Voltage Gain: range 1.03 – 1.05 Float 1
7678 7679 IDM_AI1VOLTOFF W4 AI1 Voltage Offset: range -(122.6 to 146.6) Float 0
7680 7681 IDM_AI2VOLTGAIN W4 AI2 Voltage Gain: range 1.03 – 1.05 Float 1
7682 7683 IDM_AI2VOLTOFF W4 AI2 Voltage Offset: range -(122.6 to 146.6) Float 0
7684 7685 IDM_AI3VOLTGAIN W4 AI3 Voltage Gain: range 1.03 – 1.05 Float 1
7686 7687 IDM_AI3VOLTOFF W4 AI3 Voltage Offset: range -(122.6 to 146.6) Float 0
7688 7689 IDM_AI4VOLTGAIN W4 AI4 Voltage Gain: range 1.03 – 1.05 Float 1
7690 7691 IDM_AI4VOLTOFF W4 AI4 Voltage Offset: range -(122.6 to 146.6) Float 0
7692 7693 IDM_AI5VOLTGAIN W4 AI5 Voltage Gain: range 1.03 – 1.05 Float 1
7694 7695 IDM_AI5VOLTOFF W4 AI5 Voltage Offset: range -(122.6 to 146.6) Float 0
7696 7697 IDM_OVERPRESLIM W4 Overpressure Limit, range 200 to 600PSIA Float 450
7698 7699 IDM_MAXINTERR W4
Maximum integral position control
contribution, units of velocity. Range 0.0 to
1.999
Float
0.0000
13
7700 7701 IDM_TR W4
Thermal aging reference temperature, units of
deg C. Range: 0.0 to 150.0
Float
60.0
7702 7703 IDM_TITDB W4
Total inches traveled accumulator dead-band,
units of inches. Range: 0.0 to 0.005
Float
0.0005
7704 7705 IDM_INPRESCOEF2 W4
Second order inlet pressure sensor correction
coefficient. Range: -1.0 to 1.0
Float
0.0
7706 7707 IDM_OUTPRESCOEF2 W4
Second order inlet pressure sensor correction
coefficient. Range: -1.0 to 1.0
Float
0.0
Table 16: General Setup Parameters
9.1.2 Position Interpolation Parameters
The XVG/eXVG Fuel Metering Valve can be configured to operate with a non-linear
stroke profile by adjusting the values in this table. The Position Interpolation Table is a
43-point table, which maps a specific position to a linear demand position point. The first
30 points in the table are spaced at 0.1mA intervals and the remaining points are spaced
at 1.0mA intervals.